Proteus rainscreens are fire rated cladding systems, tested & classified for fire performance.
Proteus rainscreen products are fire rated cladding systems, that have been fully tested and classified to meet the required fire performance standards for construction products.
WarringtonFire has classified our systems in accordance with the Euroclass system for reaction to fire of construction products. EN 13501-1 classification is based on single burning item tests (BS EN 13823) for each panel specification, along with calorific data (BS EN ISO 1716 or BS EN ISO 1182) for each individual material layer that make up the panel.
This confirms the panels are of very limited combustibility or non-combustible and can be used in façades of all heights without further testing, provided all other materials within the wall build-up are also A2-classified.
Classifications
Listed below are the full classifications for each product specification, including sub-classifications for smoke production and flaming droplets.
Material
1.5mm Polyester Powder Coated Aluminium
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm Polyester Powder Coated Steel
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.8mm Stainless Steel
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm Classic Copper
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm Brass Copper Alloy
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm Bronze Copper Alloy
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
1.5mm Anodised Aluminium
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm Pre-Coated Steel
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
1.0mm Weathering Steel
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
3.0mm Vitradual Aluminium
Reaction To Fire Standard
EN 13501-1
Classification
A1
Material
3.0mm Polyester Powder Coated Aluminium
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.9mm to 5.0mm Polyester Powder Coated Aluminium
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
0.7mm to 3.0mm Polyester Powder Coated Steel
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
4.0mm Back Painted Toughened Glass
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
3.0mm Porcelain Ceramic
Reaction To Fire Standard
EN 13501-1
Classification
A2-s1, d0
Material
Occam Brick Slip
Reaction To Fire Standard
EN 13501-1
Classification
A1
Material
Occam Clay Tile
Reaction To Fire Standard
EN 13501-1
Classification
A1